Showing results: 46 - 60 of 68 items found.
-
40-194A-001-HI -
Pickering Interfaces Ltd.
The 40-194A-001 is a 7-Channel PXI Fault Insertion switch with hardware interlock and one fault bus, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
40-194A-002-HI -
Pickering Interfaces Ltd.
The 40-194A-002 is a 7-Channel Fault Insertion switch with hardware interlock and two fault buses, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
42-203-001 -
Pickering Interfaces Ltd.
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
42-203-002 -
Pickering Interfaces Ltd.
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
40-203-001 -
Pickering Interfaces Ltd.
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
40-203-002 -
Pickering Interfaces Ltd.
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
778572-10 -
NI
68-Channel, 2 A PXI Signal Insertion Switch Module—The PXI‑2510 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2510 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls
-
OTM-XB -
Zensol Automation Inc.
The OTM-XB is the only standalone recorder to use the vibro-acoustic method that detects intermittent and sporadic operational faults on working circuit breakers.
-
A. Eberle GmbH & Co. KG
The fault recorders and power quality analyzers PQI-D, PQI-DA and PQI-DA smart are the key devices for all measurement tasks in low-, medium- and high-voltage grid.
-
Qualitrol
Multi-functional fault recorder including: -- Disturbance fault record (DFR)- Dynamic disturbance recording (DDR) - Phasor measurement unit (PMU C37-118)- Power Quality (PQ Class A)- Travelling wave fault location (TWS to +/-60m) - Impedance fault location- Protocols (61850, Modbus, DNP3) - Sequence of event recording (SOE)- GPS, IRIG and NTP time sync- iQ+ masterstation software.
-
TESLA LITE -
ERLPhase Power Technologies Ltd
The new TESLA LITE is an economical user-friendly multi-timeframe power system recorder: Economical yet complete power system recording for custom applications in smaller substations. Easy to use intuitive software Simultaneous transient fault, dynamic swing and trend recording and event logging Fault location derived from single and calculated currents IRIG-B clock synchronization (modulated and unmodulated) Smallest footprint among recorders allows easy retrofit and installation 12 current, 6 voltage and 38 digital inputs
-
GDJB -1200 -
HV Hipot Electric Co.,Ltd.
Relay Protection microcomputer test device play a key role in operating electricity power systems reliably and safely.It is the testing device used in professional field of microcomputer protection,relay protection,excitation measurement,fault recorder.
-
GDJB-902 -
HV Hipot Electric Co.,Ltd.
GDJB-902 Relay Protection microcomputer test device play a key role in operating electricity power systems reliably and safely.It is the testing device used in professional field of microcomputer protection,relay protection,excitation measurement,fault recorder.
-
2002 -
Utility Systems Inc.
The Model 2002 DME System is a state of the art, multifunction data collection and analysis system. It is suitable for application in an electrical utility substation or plant environment to produce Sequence of Event (SER), Digital Fault Recorder (DFR), Dynamic Disturbance Recorder (DDR), and Continuous Recorder data in conformance with PRC-002-1 and PRC-018-1. All data recorded by the DME system is stored in IEEE C37.111 format and named in conformance with IEEE C37.232. The system also has a software option to enable the Phasor Measurement Unit (PMU) feature to provide streaming data in conformance with IEEE C37.118.
-
9000 -
Utility Systems Inc.
The Model 9000 DME System is a high performance multifunction data collection and analysis system. It is suitable for application in an electrical utility substation or plant environment to produce Sequence of Event (SER), Digital Fault Recorder (DFR), Dynamic Disturbance Recorder (DDR), and Continuous Recorder data in conformance with PRC-002-1 and PRC-018-1. All data recorded by the DME system is stored in IEEE C37.111 format and named in conformance with IEEE C37.232. The system also has a software option to enable the Phasor Measurement Unit (PMU) feature to provide streaming data in conformance with IEEE C37.118.